@@ -1059,7 +1059,11 @@ INSERT INTO `iot_alarm_system_field`(`id`, `source_type`, `source_type_des`, `s
|
|
|
INSERT INTO `iot_alarm_system_field`(`id`, `source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (158, 408, 'UPS', '408_4', '电池容量', 'batteryCapacity', '{}', '{}', 'FLOAT', '浮点型', '%', 1, NULL, NULL, NULL, NULL);
|
|
|
INSERT INTO `iot_alarm_system_field`(`id`, `source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (159, 408, 'UPS', '408_5', '电池剩余备用时间', 'batteryRemainingStandbyTime', '{}', '{}', 'FLOAT', '浮点型', 's', 1, NULL, NULL, NULL, NULL);
|
|
|
INSERT INTO `iot_alarm_system_field`(`id`, `source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (160, 408, 'UPS', '408_6', '电池电压低告警', 'lowBatteryVoltageAlarm', '{\"0\": \"正常\",\"1\": \"告警\"}', '{\"EQUALS\": \"等于\"}', 'ENUM', '枚举', NULL, 1, NULL, NULL, NULL, NULL);
|
|
|
-INSERT INTO `iot_alarm_system_field`(`id`, `source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (161, 4186, '8小时回路', '4186', '8小时回路通电状态', 'status', '{\"0\": \"断电\",\"1\": \"通电\"}', '{\"EQUALS\": \"等于\"}', 'ENUM', '枚举', NULL, 1, NULL, NULL, NULL, NULL);
|
|
|
+INSERT INTO `iot_alarm_system_field`(`id`, `source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (161, 4186, '回路', '4186', '回路通电状态', 'status', '{\"0\": \"断电\",\"1\": \"通电\"}', '{\"EQUALS\": \"等于\"}', 'ENUM', '枚举', NULL, 1, NULL, NULL, NULL, NULL);
|
|
|
+INSERT INTO `iot_alarm_system_field`(`id`, `source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (162, 41861, 'DO8小时控电箱按钮', '41861', 'DO8小时控电箱按钮', 'status', '{\"0\": \"弹起\",\"1\": \"按下\"}', '{\"EQUALS\": \"等于\"}', 'ENUM', '枚举', NULL, 1, NULL, NULL, NULL, NULL);
|
|
|
+INSERT INTO `iot_alarm_system_field`(`id`, `source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (163, 41860001, '8小时回路通电状态', '41860001', '8小时回路通电状态', 'status', '{\"0\": \"断电\",\"1\": \"通电\"}', '{\"EQUALS\": \"等于\"}', 'ENUM', '枚举', NULL, 1, NULL, NULL, NULL, NULL);
|
|
|
+INSERT INTO `iot_alarm_system_field`(`id`, `source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (164, 41860002, '24小时回路缺相状态', '41860002', '24小时回路缺相状态', 'status', '{\"0\": \"缺相\",\"1\": \"通电\"}', '{\"EQUALS\": \"等于\"}', 'ENUM', '枚举', NULL, 1, NULL, NULL, NULL, NULL);
|
|
|
+
|
|
|
-- 报警主机传感器 --
|
|
|
INSERT INTO `iot_alarm_system_field`(`source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (500, '湿度(报警主机)', 'AlarmHostInput_Humidity', '湿度', 'status', '{\"alarm\": \"报警\",\"bypassAlarm\": \"旁路报警\",\"bypass\": \"旁路\",\"normal\": \"正常\",\"activity\": \"活动\",\"unknow\": \"未知\"}', '{\"EQUALS\": \"等于\"}', 'ENUM', '枚举', NULL, 1, NULL, NULL, NULL, NULL);
|
|
|
INSERT INTO `iot_alarm_system_field`(`source_type`, `source_type_des`, `sys_field_code`, `name`, `property_name`, `specs`, `operators`, `type`, `type_des`, `unit`, `enable`, `create_by`, `create_time`, `update_by`, `update_time`) VALUES (500, '温度(报警主机)', 'AlarmHostInput_Temperature', '温度', 'status', '{\"alarm\": \"报警\",\"bypassAlarm\": \"旁路报警\",\"bypass\": \"旁路\",\"normal\": \"正常\",\"activity\": \"活动\",\"unknow\": \"未知\"}', '{\"EQUALS\": \"等于\"}', 'ENUM', '枚举', NULL, 1, NULL, NULL, NULL, NULL);
|